    Phantoms for Quality Assurance
    Detection - Fiducial Markers

    Phantoms for Quality Assurance

    X-LITE

    X-LITE is used to check light and radiation field coincidence.It consists of a fluorescent plate, active area 20x20 cm with scales. The plate is activated by exposure to ionising radiation, which produces fluorescence with a lifetime of few minutes.

    A removable red filter over the active surface protects the fluorescent plate from activation by ambient light or by the gantry field light. After irradiation the fluorescent response can be compared with the set-up field size on the scale.

    xlite.jpg
    Primus L

    Test device Primus L. Suitable for image quality checks at planar kV and MV (EPID) units.

    primus l.jpg
    Round CT and RTPS QA Phantom

    For calibration and verification of the treatment planning system and CT simulator with regard to the Hounsfield Units (HU).

    Including:

    • Cubic phantom for head and neck and stereotactic applications (item number BS41-000)
    • RW3 adapter shells for upgrading the cubic phantom to a round geometry (item number BS41-300)
    • Transportation case
    round ct and rtps.jpg
    Inserts for Round CT and RTPS QA Phantom

    Set of inhomogeneous inserts for round CT and RTPS QA phantom.

    Hollow inserts with 1.7 cm diameter and 16 cm length embedded in 2 x 2 cm RW3 block.

    Consisting of:

    • Insert with Water (to be filled with water prior to measurement)
    • Lung with a physical density of 0.20 g/ccm and electron density rel. to water 0.194
    • Adipose with a physical density of 0.97 g/ccm and electron density rel. to water 0.946
    • Muscle with a physical density of 1.06 g/ccm and electron density rel. to water 1.048
    • Bone with a physical density of 1.640 g/ccm and electron
    inserts for round ct.jpg
    Advanced Holder for MatriXX

    Advanced holder for MatriXX for mounting to accelerator gantry

    Including adjustable XY table with high precision knobs for additional flexibility of extremely accurate positioning.

    Very fine lateral (relative to the radiation field) and angular (about the central axis of the beam) adjustment of the MatriXX.

    advanced holder.jpg
    Holder for StarTrack* and MatriXX

    Holder for StarTrack* and MatriXX for mounting to accelerator gantry

    Including non-adjustable XY table.

    The center of the StarTrack* / MatriXX can be adjusted manually to the radiation field axis.

    holder for startrack.jpg
    Gantry Fixture for StarTrack* / MatriXX Gantry fixture for StarTrack* / MatriXX gantry holder available for 76 an 100 cm SSD. Available for Siemens, Elekta and Varian Linacs (Elekta 100cm shown). gantry fixture.jpg