Detectors, Holders & Build-up Caps
Plan Delivery Verification
Phantoms for Quality Assurance
Detection - Fiducial Markers

Detectors, Holders & Build-up Caps

Compact Thimble Ion Chamber CC01

Ion chamber: 0.01 ccm, for stereotactic, IMRT and any small field measurements, TNC triax -not recommended for use in absolute dosimetry due to small volume.

compact thimble ion chamber cc01.jpg
Compact Thimble Ion Chamber CC04 Ion chamber: 0.04 ccm, shonka plastic, waterproof, for stereotactic, IMRT or any small field measurements compact thimble ion chamber cc04.jpg
Compact Thimble Ion Chamber CC08 Ion chamber: 0.08 ccm, shonka plastic, waterproof compact thimble ion chamber cc08.jpg
Compact Thimble Ion Chamber CC13 Ion chamber: 0.13 ccm, shonka plastic, waterproof

compact thimble ion chamber cc13.jpg
Compact Thimble Ion Chamber CC25 Ion chamber: 0.25 ccm, shonka plastic, waterproof compact thimble ion chamber cc25.jpg
"Farmer" Type Ion Chamber FC65-P

The Farmer type chamber FC65-P is an air cavity ionization chamber, vented through a waterproof silicon sleeve. It is waterproof and fully guarded.

The watertight chamber consists of a conducting plastic thimble outer electrode and a pure aluminum inner electrode, which are supported by a thin aluminum stem. The stem is connected to a 1.40-m cable shielded by a watertight silicon sleeve that allows for air ventilation.

The chamber is designed preferably for the energy ranges of photons and electrons at medical accelerators. It can also be employed in X-ray beams with generating potentials from 70 kV to 280 kV and for gamma radiation of 137Cs and 60Co. The energy range of proton beams with available chamber factors is between 50 and 250 MeV.

farmer ion chamber fc65p.jpg
"Farmer" Type Ion Chamber FC65-G

The FC65-G is an air ionization chamber, vented through a waterproof silicon sleeve. It is waterproof and fully guarded.

The chamber is designed preferably for the energy ranges of photons and electrons at medical accelerators. It can also be employed in X-ray beams with generating potentials from 70 kV to 280 kV and for gamma radiation of 137Cs and 60Co. The energy range of proton beams with available chamber factors is between 50 and 250 MeV.

farmer ion chamber fc65g.jpg
"Farmer" Type Ion Chamber FC23-C

The Farmer type chamber FC23-C is an air cavity ionization chamber, vented through a waterproof silicon sleeve. It is waterproof and fully guarded.

The watertight chamber consists of conducting plastic outer and inner electrodes, supported by a thin aluminium stem. The stem is connected to a 1.40-m cable shielded by a watertight silicon sleeve that allows for air ventilation.

The chamber is designed preferably for the energy ranges of photons and electrons at medical accelerators. It can also be employed in X-ray beams with generating potentials from 70 kV to 280 kV and for gamma radiation of 137 Cs and 60 Co. The energy range of proton beams with available chamber factors is between 50 and 250 MeV.

farmer ion chamber fc23c.jpg
Parallel Plate Ion Chambers for Electron Beam PPC05

PPC05 is an air-cavity ionization chamber with high spatial resolution.
The construction materials are air equivalent conducting plastic Shonka C552 (housing, entry window and side walls) and highly insulating plastics PEEK and PPE. The collecting electrode material is graphitized PEEK.

The chamber is constructed with a circular sensitive volume of planar geometry covered by a rigid 1 mm thick entry window. The small collecting volume with 0.6 mm plate spacing, 9.9 mm diameter and a 3.4-mm-wide guard ring enables excellent resolution in depth dose studies and requires a small perturbation correction. The chamber is waterproof and vented through a silicone sleeve.

parallel plate ion chamber for ppc05.jpg
Parallel Plate Ion Chambers for Electron Beam PPC40

PPC40 Parallel plate ion chamber for electron beams, 0.4 ccm
As designed and constructed by PTB Braunschweig, M. Roos, K. Derikum, D. Lange. The chamber is entirely made from PMMA; electrode areas are additionally graphitized. The waterproof chamber is vented through a silicone sleeve and it is constructed with a circular sensitive volume of planar geometry covered by a rigid 1 mm thick front window.

The combination of design and material minimizes perturbation components, the in-scattering and the backscatter effect, to a perturbation correction factor equal to unity.
As an associated measuring instrument for precise absolute dose determinations, in calibration dosimetry, compliance testing or installation and set-up of treatment machines or other new equipment, it is recommended to use the reference-class therapy dosimeter Dose1 or Dose2.

parallel plate ion chamber for ppc40.jpg
NACP Parallel Plate Ionization Chamber

The NACP Chamber is designed according to the recommendations of the Nordic Association of Clinical Physicists (NACP).

The collecting electrode is manufactured of graphitized polystyrene. The Parallel Plate NACP Chamber is produced by IBA Dosimetry, Germany.

The major part of NACP chamber cable is surrounded by a transparent and water-proof plastic tube to protect from water and ensure the active volume ventilation when the chamber is immersed in water.

Inside the tube, there are two humidity indicators. The indicator colour changes according to the humidity of the environment. Only white colour of the indicator indicates that the humidity is suitable for the chamber operation.

nacp parallel plate ionisation chamber.jpg
The Stealth CHAMBER The StealthCHAMBER is designed to ensure that a reference signal is available for all field sizes (up to 20x20cm with special focus in SRS, SBRT, small field dosimetry commissioning and QA) in continuous and/or in step-by-step scanning mode.
Available with TNC Triax connector.
 
It can be securely mounted with custom or vendor-specific holders in the beam where it does not shadow the field chamber/detector for the entire area of programmed positions, in order to produce accurate and reproducible scans.
stealth chamber.jpg

For more information on chambers, please email us or call Mark Sweeney on 09 580 1959

EFD Diode Field Detector EFD diode field detector, electron beams

efd diode field detector.jpg
PFD Diode Field Detector PFD diode field detector, photon beams pfd diode field detector.jpg
RFD Diode Reference Detector The reference detector is used only to obtain a reference signal for relative field measurements. By calculating the quotient of the field and the reference signals, the effect of the variations in the accelerator output is eliminated. rfd diode reference detector.jpg
Razor Detector

Diode detector with very low dose rate dependency, effective measurement depth 0.50 mm from surface, very high geometric resolution (0.6 mm in plane perpendicular to central axis, 0.06 mm in depth).

The Razor detector for relative dosimetry is a very small sized, rigid and long-lasting semiconductor detector with high dosimetric performances.

The Razor detector is based on a p-type silicon diode chip, specifically designed for radiation therapy applications, and in particular for the relative dosimetry of electron and stereotactic photon fields. Performances have been verified in the range of photon beam qualities 60Co-15MV, and 6-15MeV electron energies.

razor detector.jpg
LDA-99 SC Linear Detector Array

5x faster Beam Profile Measurements!
For fast and accurate commissioning of dynamic and virtual wedges as well as fast acquisition of standard inplane, crossplane and diagonal beam profiles.
Completely integrated in myQA Accept. Data transfer via Ethernet connection.

Each item includes:

  • LDA-99 SC detector array consisting of 99 Hi-pSi diode detectors with the highest spatial resolution of 5 mm between detector
  • One reference detector
  • emXX electrometer with 99 + 1 channels, 100-240V, 50/60Hz, one power cord included for either 230V plug, USA, UK, Australia or China.
  • Holder for mounting the detector array in the corresponding water phantom
  • 15 mm build-up for in-air measurements
lda99 sc linear detector array.jpg
Small Universal Detector Holder Small Universal Detector Holder for compact thimble ionization chambers and diode detectors as well as third party detectors with a diameter of 4 mm to 10 mm

small uni detector holder.jpg
Large Universal Detector Holder Large Universal Detector Holder for compact thimble and Farmer type ionization chambers as well as third party detectors with a diameter of 10 mm to 15 mm

large uni detector holder.jpg
Universal parallel plate chambers Detector Holder Universal parallel plate chambers Detector Holder uni parallel plate chambers detector holder.jpg

For more information on detectors, please email us or call Mark Sweeney on 09 580 1959

Nickel-Silver Caps Set of 8 caps for ion chamber CC13, made of Nickel-Silver (density 8.62 g/cm³) for Helax TMS, Elekta Renderplan/Preciseplan and Nucletron Oncentra Masterplan. Energy ranges: Co-60, 4-6 MV, 8-10 MV, 10-12 MV, 12-15 MV, 15-18 MV, 18-20 MV, 20 - 23 MV. Request more information on caps. nickel silver caps.jpg
Nickel-Silver Caps for CC04 Cap for CC04, 4 - 6 MV. Request more information on caps. cap for cc04 1.jpg
Nickel-Silver Caps for CC04 Cap for CC04, 8 - 10 MV. Request more information on caps. cap for cc04 2.jpg
Nickel-Silver Caps for CC04 Cap for CC04, 10 - 12 MV. Request more information on caps. cap for cc04 3.jpg
Nickel-Silver Caps for CC04 Cap for CC04, 12 - 15 MV. Request more information on caps. cap for cc04 4.jpg
Nickel-Silver Caps for CC04 Cap for CC04, 15 - 18 MV. Request more information on caps. cap for cc04 5.jpg
Nickel-Silver Caps for CC04 Cap for CC04, 18 - 20 MV. Request more information on caps. cap for cc04 6.jpg
Brass Build-up Caps for PFD and EFD Set of 5 brass build-up caps for PFD and EFD 3G-pSi field detectors for in-air measurements for Helax TMS, Elekta Renderplan/Preciseplan and Nucletron Oncentra Masterplan ( 2, 4, 6, 8 and 10 mm wall thickness). Request more information on caps. brass build up caps.jpg
Build-up Caps for CC04 28 mm diameter for 4 - 6 MV photon and 8 - 12 MeV electron. Request more information on caps. build up cap for cc04 1.jpg
Build-up Caps for CC04 38 mm diameter for 6 - 10 MV photon and 12 - 18 MeV electron. Request more information on caps. build up cap for cc04 2.jpg
Build-up Caps for CC04 48 mm diameter for 10 - 15 MV photon and > 18 MeV electron. Request more information on caps. build up cap for cc04 3.jpg
Build-up Caps for CC04 58 mm diameter for 15 - 20 MV photon. Request more information on caps. build up cap for cc04 4.jpg
Build-up Caps for CC04 78 mm diameter for 20 - 30 MV photon. Request more information on caps. build up cap for cc04 5.jpg
PMMA Build-up Caps for CC13 13 mm diameter for 1 - 4 MV photon and 4 - 8 MeV electron. Request more information on caps. build up cap for cc13 1.jpg
PMMA Build-up Caps for CC13 30 mm diameter for 4 - 6 MV photon and 8 - 12 MeV electron. Request more information on caps. build up cap for cc13 2.jpg
PMMA Build-up Caps for CC13 40 mm diameter for 6 - 10 MV photon and 12 - 18 MeV electron. Request more information on caps. build up cap for cc13 3.jpg
PMMA Build-up Caps for CC13 50 mm diameter for 10 - 15 MV photon and > 18 MeV electron. Request more information on caps. build up cap for cc13 4.jpg
PMMA Build-up Caps for CC13 60 mm diameter for 15 - 20 MV photon. Request more information on caps. build up cap for cc13 5.jpg
PMMA Build-up Caps for CC13 80 mm diameter for 20 - 30 MV photon. Request more information on caps. build up cap for cc13 6.jpg
PMMA Build-up Caps for FC65-G / FC65-P 30 mm diameter for 4- 6 MV photon and 8 - 12 MeV electron. Request more information on caps. pmma build up 1.jpg
PMMA Build-up Caps for FC65-G / FC65-P 40 mm diameter for 6-10 MV photon and 12 - 18 MeV electron. Request more information on caps. pmma build up 2.jpg
PMMA Build-up Caps for FC65-G / FC65-P 50 mm diameter for 10-15 MV photon and 18 MeV electron. Request more information on caps. pmma build up 3.jpg
PMMA Build-up Caps for FC65-G / FC65-P 60 mm diameter for 15 - 20 MV photon. Request more information on caps. pmma build up 4.jpg

For more information on caps, please email us or call Mark Sweeney on 09 580 1959

Triaxial Detector Cables TNC triax connectors triax detector cable 1.jpg
Triaxial Detector Cables BNC triax connectors triax detector cable 2.jpg
Triaxial Detector Cables

NACP - BNC / Banana Connector. This type of connector is used if the signal and the guard are kept at ground potential, and the polarizing voltage (high voltage) is applied via a banana jack to the chamber.

triax detector cable 3.jpg

For more information on connecting cables, please email us or call Mark Sweeney on 09 580 1959